MUFENG INSULATION

November 9, 2026

Fiberglass Sleeving for Electric Motors: Protecting the Lead Wire Inside

Discuss Your Requirements

Contents

· Introduction

· Where fiberglass sleeving for electric motors is used

· The environment inside the frame

· Choosing the voltage class for a motor

· Sizing fiberglass sleeving for electric motors

· Varnish impregnation: the test most sleeving actually faces

· Failure modes worth designing out

· Specifying and accepting

· Conclusion

· Frequently asked questions

· Sources

Introduction

Fiberglass sleeving for electric motors is a small line item that decides whether a machine passes its routine tests on the first attempt. The lead wire leaving a stator is one of the most exposed components in the whole assembly: it runs close to laminations, bends around the winding overhang, sits in a varnish bake, and then vibrates for twenty years. When it fails, the motor fails, and the cause is usually a sleeve that was too short, too thin, or made of the wrong material for the temperature inside the frame. This article maps where sleeving is used inside a motor, what each location demands, and how to size and specify it properly.

Where fiberglass sleeving for electric motors is used

Walk around a stator and the applications become obvious.

The stator lead exit is the first. Phase leads leave the winding and run to the terminal box, passing the core end and often a sharp lamination edge. This is where cut-through happens.

The phase connection between coil groups is the second. Joints are insulated with sleeving slipped over the crimp or the twisted connection before it is made off, and the sleeve has to survive the same bake as the winding.

The thermal protector and sensor leads are the third. These run from inside the winding to the terminal box and are thin, fragile, and easily pinched during assembly.

The terminal box wiring is the fourth, running from the terminal studs to the lead ends, sometimes with additional sleeving for creepage and mechanical protection.

The brake, encoder and fan leads on the non-drive end are a fifth, less obvious group. They are often forgotten in the specification and then fail in service because nobody considered the temperature at that end of the machine.

Each of those locations sees a different combination of heat, mechanical abuse and chemical exposure, and a single product will not be right for all of them.

The environment inside the frame

Three conditions dominate the design.

Temperature. Motor insulation systems are classified by thermal class, and the familiar classes run from 105 °C for class A through 130 °C for class B, 155 °C for class F and 180 °C for class H. The class describes the insulation system, not the sleeving alone, but the sleeving has to be at least as capable as the rest of the system. A class F machine with PVC sleeving on the leads is a mismatch, even if the PVC is technically rated for the ambient.

Varnish. Most stators are impregnated, usually by dip and bake or trickle, and the sleeving goes through the cure. Polyester and epoxy varnishes cure in the region of 130 to 160 °C, and some systems run higher. A thermoplastic sleeve softens in that bake, sticks to itself, and can deform into an oval that will not fit the terminal afterwards. Silicone glass sleeving does not.

Mechanical abuse. During assembly the lead is pulled, bent and pressed against the core. After assembly it vibrates. Sleeving has to resist abrasion against a lamination edge and remain flexible enough not to crack at the bend.

Choosing the voltage class for a motor

The instinct is to use the highest class available. That is expensive and usually unnecessary, but there is one case where the instinct is right: inverter duty.

Consider a 400 V three-phase motor on a PWM drive. The DC bus sits at around 565 V, since 400 V rms multiplied by the square root of two gives the peak of the rectified supply. A long cable between drive and motor causes the pulse to reflect, and the voltage at the motor terminals can approach twice the bus voltage, so roughly 1130 V. Add switching repetition and a safety margin, and a 1500 V class sleeve looks thin at the motor end of a long cable run.

Run the same arithmetic on a 690 V motor: a bus near 975 V, a reflected wave approaching 1950 V. Now a 2500 V class is marginal and a 4000 V class is the sensible choice for the lead exit. This is why inverter-duty machines often specify a higher sleeving class than the nameplate voltage would suggest, and why the decision belongs with the electrical engineer rather than the purchasing officer.

Motor location

Main exposure

Sensible sleeving

What fails if it is wrong

Stator lead at core exit

Abrasion, heat, varnish

Silicone glass, 4000V class, heavier wall

Cut-through to the lamination, earth fault

Phase connection

Heat, varnish, bending

Silicone glass, medium wall

Coating cracks at the crimp, creepage loss

Thermal protector leads

Heat, fine wire, handling

Thin-wall silicone glass

Sleeve slips off, lead chafes on the end winding

Terminal box wiring

Creepage, occasional contact

Silicone glass or PVC depending on temperature

Tracking across a contaminated surface

Brake and encoder leads

Heat at the non-drive end, oil

Silicone glass where temperature demands it

Embrittlement, cracked insulation

 

Sizing fiberglass sleeving for electric motors

Bore, expansion and wall

Get the size wrong and nothing else matters.

Braided sleeving is ordered by nominal bore and expands over a stated range. The bore should be large enough to slide over the terminal, the crimp or the connector without forcing, and small enough that the sleeving grips the wire once installed. If it is too loose, it migrates along the lead during handling and ends up somewhere other than where the drawing put it.

Wall thickness follows the voltage class and the mechanical risk. A lead crossing a lamination edge wants a heavier wall than one running in free air, even at the same voltage. This is a place where a single part number across a whole machine is a false economy.

Length is the detail that causes most defects. The sleeve should extend past the end of the exposed conductor and past any sharp transition, and it should be positioned so that the end cannot creep back into the winding during the bake. A common failure is a sleeve cut to nominal length with no allowance for the crimp barrel, leaving two millimetres of bare conductor where the creepage path was supposed to be.

Varnish impregnation: the test most sleeving actually faces

Trickle impregnation is a good screening test for a sleeving, even if it is not the one on the data sheet. Resin runs over the sleeve, fills the braid if the coating is porous, and then cures hard. Two things can go wrong.

If the coating does not fully cover the braid, resin wicks into the glass and hardens it. The sleeve becomes rigid, loses flexibility at the bend, and can crack when the lead is dressed into the terminal box. If the coating is complete, the resin sits on the surface and the sleeve stays flexible underneath.

The second problem is adhesion. A sleeve that bonds permanently to the winding is difficult to rework, and one that shrinks or deforms in the bake will not fit its terminal. Silicone's release behaviour is an advantage here, and it is one reason silicone glass is used rather than a thermoplastic in this position even where the temperature would allow one.

Failure modes worth designing out

Cut-through at a lamination edge. The classic failure. It is a mechanical problem, solved by a heavier wall, a longer sleeve, or a routed lead that avoids the edge. Adding a second layer of sleeving at the crossing point is cheaper than a warranty claim.

Frayed ends. Loose glass yarns at the cut end can bridge a creepage path, and they shed fibres into the winding. Specify a hot-cut or sealed end, or at least a cut that has been inspected.

Slippage. A sleeve that is not retained moves along the lead. In some designs a tie or a formed bend holds it, in others the fit alone has to do the work.

Embrittlement. Heat ageing hardens the coating, and a hardened sleeve cracks at the bend. This is why the flexibility-after-ageing test exists and why a supplier's temperature claim should be read as a continuous rating rather than a peak.

Wrong colour in the wrong place. Colour coding of phase and function leads is a genuine aid to assembly and service. It is also a specification item, not an afterthought, and it is one of the reasons sleeving is offered in multiple colours across a 1 to 20 mm bore range.

Specifying and accepting

A workable motor sleeving specification has six lines: product type and coating family, voltage class with the test basis, bore and expansion range, wall thickness, colour, and cut length with end finish. Add the temperature rating and any declaration required by the end customer.

For acceptance, check the bore and wall on samples from each reel, bend a sample around a mandrel close to its own diameter after a short heat soak, and pull one over a representative terminal to confirm the coating is not shaved. If the motor is safety-critical, a dielectric proof test on one sample per batch converts the supplier's claim into a record.

None of this is difficult, and all of it is cheaper than finding the problem at the end-of-line test.

Conclusion

Fiberglass sleeving for electric motors is selected on four things: the temperature the position actually sees, the voltage class including the transients a drive imposes, the bore and wall that fit the lead and the edge it crosses, and an end finish that will not fray in the bake. Get those right and the sleeve is invisible for the life of the machine. Get them wrong and it becomes the reason a motor fails its routine test or comes back from the field two years later. The part costs pennies; the failure does not.

Frequently asked questions

What voltage class should a 400 V motor lead use?

For a motor on a drive with a long cable run, a 4000V class is a common choice, because reflected waves can push the terminal voltage to roughly twice the DC bus. For a direct-on-line motor, a 1500V class is usually adequate. The decision belongs to the electrical design, not the purchasing list.

Can PVC sleeving be used inside a motor?

Only where the temperature allows it, which is rare for anything that goes through a varnish bake. PVC softens in the region of the impregnation cure and can deform or stick. Silicone glass sleeving is the usual choice for internal leads for that reason.

How do I choose the bore for a lead?

Measure the outside diameter of the wire, the crimp and the terminal, and pick a nominal bore that slides over the largest of them while still gripping the wire. Braided sleeving expands, so the nominal bore is a starting point rather than a fixed dimension.

Should the sleeving cover the crimp?

Yes, the sleeve should extend past the crimp barrel and any exposed conductor, with allowance for movement during the bake and during terminal assembly. A sleeve cut to nominal length commonly leaves bare conductor exposed at the joint.

Does the sleeve need to be flexible after ageing?

It does if the lead will be bent during assembly or service. Heat ageing hardens any organic coating, and a hardened sleeve cracks at a tight bend. Ask for a flexibility-after-ageing result rather than assuming the new-sample hand will persist.

← All Resources